Chartered surveyors in Poulton-le-Fylde

2 RICS surveyors covering 1 postcode district around Poulton-le-Fylde, in the North West. RICS Home Survey Level 2 and Level 3, and RICS Residential Valuation.

Poulton-le-Fylde is post-war country: three in ten homes around it went up between 1945 and 1964, nearly twice the national share, and fewer than one in twenty-five pre-date 1900. Bungalows and semis on the flat Fylde plain make up much of it. The list for those houses is wall ties, original roof coverings, chimneys and the dormers and extensions added since. The ground is low and largely clay, so drainage and any sign of movement are read with that in mind, and plots near the Wyre are checked against the flood map.

Local conditions

What we check in Poulton-le-Fylde.

Drawn from official open data for this area, not written from a template. It tells you what a survey here has to account for. It is not a substitute for the formal searches, and we say where those live.

Wyre
Building control records, conservation area status and planning history for Poulton-le-Fylde sit with Wyre. Where alterations look unauthorised we will say so, and tell you what to ask your solicitor to confirm.

Sources: Environment Agency flood areas and ONS boundary data, both Open Government Licence; coalfield extents from published Coal Authority and BGS mapping. Coalfield boundaries are indicative. A mining report is the authoritative answer for any individual property.

The housing stock in Poulton-le-Fylde.

30.1%

of homes within 2.4km of the centre were built in 1945–1964. Age is the strongest single predictor of what a survey finds, so it is where we start before we have seen the property.

Homes in Poulton-le-Fylde by construction era, compared with England and Wales
BuiltShareCompared with England & WalesHomes
Pre-19003.6%-11.9 pts1,180
1900–19297.8%-2.2 pts2,540
1930s11%+1.1 pts3,590
1945–196430.1%+13.8 pts9,820
1965–198221.2%+2.9 pts6,920
1983–199912.2%about average3,980
2000 onwards14.1%-4 pts4,600

32,630 homes across 41 statistical areas within 2.4km of the centre. The marker on each bar is the England and Wales share. Source: Valuation Office Agency, Council Tax stock of properties, © Crown copyright, Open Government Licence v3.0.

What that means on an inspection

1945–1964

Post-war rebuilding, largely cavity-walled, but including system-built and non-traditional types — reinforced concrete, steel frame and prefabricated panels — put up quickly to address the housing shortage.

What we usually find. The conventional stock of this period is usually straightforward. Non-traditional construction is a different matter: some types are designated defective, and most lenders treat them differently or decline them, which affects both mortgageability and resale.

Worth knowing. Identifying the construction type is the first job on anything of this age that does not look conventionally built. A Level 3 survey is normally the right choice here, and lending should be confirmed early.

1965–1982

Cavity walls with insulation increasingly built in, flat-roofed elements such as garages, dormers and rear additions, and a broader range of manufactured materials.

What we usually find. Flat roofs of this era are frequently on their second or third covering and are a common source of water ingress. Textured coatings applied before the mid-1980s may contain asbestos, as may some cement products, soffits and floor tiles.

Worth knowing. Asbestos-containing materials are usually safe if undisturbed and in good order, but they matter a great deal if you intend to remove ceilings, take down a garage or open up the layout.

These are tendencies of the local stock, not findings on any particular house. A well-maintained Victorian terrace can be in better order than a neglected 1990s semi, which is the entire reason a survey is done on the building in front of you rather than on its postcode.

Buying in Poulton-le-Fylde?

Tell us the property and we will send a fixed price in writing. No call centre, no pressure.

Get your fixed quote →