Concrete Lintel Failure: Signs, Repairs and Replacements
What a concrete lintel does, the failure signs a surveyor flags, and practical notes on sizing, bearing and sourcing replacements.

What a concrete lintel is and where it sits
A concrete lintel is a horizontal beam that spans an opening in a wall, such as a door, window or garage opening. It sits on the masonry each side and carries the weight of the wall, and sometimes the floor or roof, above the gap.
Concrete lintels come in two broad types. Plain concrete has no steel and only works over short spans. Reinforced concrete has steel bars cast into the bottom, where the beam is in tension, and will span much wider. In most houses built from the mid twentieth century on, the lintels over openings are pre-cast reinforced concrete.
You will also find concrete lintels above cavity walls, where a lintel spans the inner leaf and a separate one or a steel section spans the outer leaf. In a cavity wall the inner leaf usually takes the bulk of the support, because it tends to carry the floor and roof loads, while the outer leaf chiefly carries its own weight. How the two leaves are bridged matters for both load and damp, which is why a surveyor looks closely here.
Chris Bloor, on siteIn a cavity wall I always try to work out how the two leaves are bridged over the opening, because it tells me as much about damp as it does about load. More than once I have found the inner lintel doing most of the work while the outer leaf has been patched over the years. Where the leaves are tied together with a boot lintel and no separate tray, I pay closer attention. The cold inside face of a solid concrete lintel is also a spot where I often find condensation and black mould in the corners.
The failure signs a surveyor flags
Most concrete lintels do their job quietly for the life of the building. When one is failing, a few signs tend to show up together.
Cracking
Cracking in a lintel, or in the masonry directly above an opening, is worth attention. A fine crack following the mortar may be cosmetic. A crack that runs through the lintel itself, or stepped cracking spreading up and out from a corner of the opening, suggests the lintel is overloaded or has moved.
Because of the way masonry bonds together above an opening, only a small triangle of brickwork directly over the lintel actually loads it, so the weight is often more modest than it looks. That is also why disturbed or rebuilt brickwork a few courses above a window, often two or three courses, can be a sign of a past repair to a lintel or to a failed cavity tray.
Not every crack above a window is a lintel problem. Settlement, thermal movement and failed wall ties can all produce cracking near openings. We look at the pattern, the width and whether it is live before we call it.
Deflection
Deflection is sag. A lintel that has bowed downwards in the middle has been loaded beyond what it can carry, or was undersized from the start. You can sometimes see it as a dip in the brick course above, or a window frame that no longer sits square. Deflection is a structural signal and should not be ignored.
Spalling
Spalling is where the surface of the concrete breaks away, leaving the face crumbling or flaking. On a lintel it often appears on the underside or the lower edge. Frost and poor-quality concrete can cause it, but on a reinforced lintel spalling frequently points to something happening inside.
Corrosion of the reinforcement
This is the one that does the real damage. The steel bars inside a reinforced lintel are protected by the concrete cover around them. If water reaches the steel, it rusts. Rust takes up more space than the original steel, so it pushes the concrete apart from the inside. That cracks and spalls the surface, exposes more steel and speeds up the process.
The tell-tale signs are brown rust staining running out of cracks, spalled patches with steel visible behind them, and horizontal cracking that follows the line of the bars. Once the reinforcement is corroding, the lintel is losing strength and the damage will continue. This is one of the clearer cases where a concrete lintel needs proper assessment rather than a patch.
It is worth knowing why water reaches the steel in the first place. Many concrete lintels from the 1930s to the 1950s ran the full width of the wall with no cavity tray over them, so water crossing the cavity could reach both the steel and the inside face. Some were "boot" shaped with a bitumen coating on top as a crude tray, while others used a separate lead tray or, later, a polythene one. Where the tray is missing or has failed, damp and corrosion tend to follow, and the cold inside face of a solid concrete lintel can also attract condensation.
Chris Bloor, on siteRust staining is the one I don't like to see. When I spot brown streaks bleeding out of the underside of a lintel, or a horizontal crack running the length of it, I know the steel inside is already corroding and the concrete is being pushed apart from within. By then it's rarely a surface job. I had a 1950s bay window last year where the owner had filled and painted the underside twice, and the stains kept coming back through. That's the tell. The damage is working outward, and a fresh coat of filler only hides the clock running down.
Repair or replace
What happens next depends on how far the lintel has gone.
| Situation | Likely action |
|---|---|
| Hairline surface crack | Monitor, often cosmetic |
| Light spalling, no steel showing | Local repair, protect from water |
| Rust staining and exposed steel | Assess strength, likely replace |
| Visible deflection or sag | Structural engineer, replace |
| Cracking spreading into the wall | Investigate cause before repair |
Minor spalling with no exposed steel can sometimes be cut back and repaired, then kept dry. Once the reinforcement is corroding and the lintel has lost section, repair is usually a short-term measure and replacement is the sounder route.
Sourcing a replacement and getting the sizing right
For a standard opening, pre-cast concrete lintels are a stock item. You can buy concrete lintels from Wickes and other builders' merchants in common widths and lengths, and a Wickes concrete lintel will suit many straightforward door and window spans in a cavity or solid wall.
That said, a lintel is a structural component, and a few things need to be right before anything is ordered.
Span and bearing
The lintel has to be long enough to span the opening and still sit properly on the masonry each side. That seating is the bearing. As a rule of thumb, a minimum bearing of around 150mm each end is expected on many standard lintels, but you should always follow the manufacturer's figure for the product you are using. Too little bearing and the load is concentrated on the edge of the wall below.
Load above the opening
A lintel over a window carrying only a bit of brickwork is a different job from a lintel carrying a floor or a roof. The load decides the depth and type of lintel you need. A stock concrete lintel sized for a light load is not a substitute for one specified for a heavy one. If you are unsure what sits above the opening, that is a reason to ask.
Damp and the cavity
If you are replacing a lintel in a cavity wall, the detail that keeps water out, the cavity tray and any weep holes, needs to be reinstated. The tray sits over the lintel and steps up across the cavity to throw any water running down the cavity back out to the face, and the weep holes let it escape. There should be at least one weep hole each side of the opening. Getting the structure right and the damp detail wrong just moves the problem. Our guide to the damp proof course covers how these details tie together.
When to involve a structural engineer
Replacing a lintel means temporarily supporting the wall above while the old one comes out. That is not a job to improvise.
We recommend a structural engineer where the lintel has visibly deflected, where cracking has spread into the wall above, where the opening is wide or carries a floor or roof, or where you simply cannot tell what the lintel is doing. The engineer sizes the replacement for the actual load and specifies how the wall is propped during the work.
If a survey has flagged a lintel and you are weighing up the implications before you commit, the point of a report is to tell you how serious it is and what to do about it. A Level 2 or Level 3 survey will set out the lintel condition in context. Lintel movement near openings can also sit alongside other issues, so it is worth reading it next to our notes on settlement and cracks.
Frequently asked questions
How do I know if my concrete lintel is failing?
Look above doors and windows for cracking, a downward sag in the brick course, surface concrete flaking away, or brown rust stains running out of the concrete. Any of these, and particularly rust with exposed steel, suggests the lintel needs assessing rather than ignoring.
Can I buy a concrete lintel from Wickes?
Yes. Suppliers such as Wickes stock pre-cast concrete lintels in standard widths and lengths that suit many ordinary door and window openings. The product is readily available: the care goes into choosing the right size and type for the span and the load above, and making sure the bearing each end is adequate.
How much does a concrete lintel need to overlap the wall?
The amount it sits on the masonry each side is the bearing, and many standard lintels expect a minimum of around 150mm each end. Always follow the manufacturer's stated figure for the product. Too little bearing concentrates the load and can crack the wall below the ends.
Do I need a structural engineer to replace a lintel?
For a wide opening, a lintel carrying a floor or roof, visible deflection, or cracking that has spread into the wall, we recommend one. The engineer sizes the replacement for the real load and specifies how the wall is supported while the old lintel is removed.
Is a cracked lintel always a serious problem?
Not always. A fine crack in the mortar can be cosmetic, and some cracking near openings comes from settlement or thermal movement rather than the lintel itself. The width, the pattern and whether the crack is still moving decide how serious it is, which is what a surveyor assesses.
More on common defects
How Deep Are Foundations for a House? A Surveyor's Guide
Domestic foundations are often around 0.9m to 1.5m deep, but the right depth depends on soil, trees and ground conditions. Here is what drives it.
ReadDamp Proof Course: Types, Costs and Regulations
What a damp proof course is, the main types including injected systems, realistic costs and the regulations that apply.
ReadChimney Stack Repair: A Buyer's Guide to Faults and Costs
What chimney stack repair involves, from the faults a survey flags to repointing, partial and full rebuilds, with indicative cost ranges and what a RICS survey picks up before you buy.
ReadNeed a survey on a specific property?
Tell us the address and we will send a fixed price in writing, with no obligation.
Get your fixed quote